The PCDU has 3 three-phase inputs, 200VAC 400Hz, 115VAC 400Hz, and 115VAC 400Hz. There is one AC output at 400Hz. AC output voltage value is selectable with relays. There are 6 DC output channels with variable current levels at 30VDC output voltage. DC outputs can provide both remote sense and local sense feature. Desired loads can be energized with a normally-open solid state switch in DC outputs. DC output currents and voltages are instantly monitored. Instant energy measurement of 2 different AC inputs and AC-DC system is provided.
PCDU | |
Configuration Abilities | • Overcurrent configuration for • Output Channel ON/OFF Control • DC Output Remote/Local Sensing Selectable |
Monitoring | • Load Current • Input Voltage • Output Voltage • Temperature • Energy metering |
Protections | • Short circuit • Overcurrent • Overvoltage • Under voltage |
Controller | • Zynq 7020 Series SoC |
• Power Distribution Unit
• Power Conversion Unit
PCDU | |
Output Channels | 6 x DC Output Channels (Generated from AC3 Input) • DC1: 40 A • DC2: 5 A • DC3: 10 A • DC4: 10 A • DC01: 15A • DC02: 3.5A
1 x AC 3 Ph Output Channels • 8.7A / 15A per phase [Selectable] (Either 200VAC or 115VAC) |
Discrete Inputs | 4 x 28V/GND 9 x Open/Short |
Discrete Outputs | 4 x 28V/GND |
Communications | 2 x RS485 4 x ETH |
PCDU | |
Input Voltage | AC1 115VAC 3 Ph Star (400 Hz) AC2 200VAC 3 Ph Star (400 Hz) AC3 115VAC 3 Ph Delta (400 Hz) |
Dimension (L X W x H) (mm) | 600 x 510 x 200 |
Weight (kg) | 40 ± 1 |
• Temperature Operating: -40°C to +60°C
• MIL-STD-810H
• MIL-STD-704F
• MIL-STD-461F
TRL 7/9