Peripheral Equipment Power Conversion Unit

Demo Product Image Watch the Promotional Video

Product Overview

The PEPCU has 3 three-phase inputs, 440VAC 400Hz, 440VAC 60Hz, and 115VAC 60Hz. There are four AC outputs in 440VAC, two at 400Hz and two at 60Hz. There are 18 DC output channels with variable current levels at 28VDC output voltage. Desired loads can be energized with a normally-open solid state switch in DC outputs and AC outputs. DC output currents and voltages are instantly monitored. Instant energy measurement of 4 different AC inputs and AC-DC system is provided. Device mount type is rack and panel.

 PEPCU
Configuration Abilities

• Overcurrent configuration for
output channel

• Output Channel ON/OFF Control

Monitoring

• Load Current

• Input Voltage

• Output Voltage

• Temperature

• Energy metering

Protections

• Short circuit

• Overcurrent

• Overvoltage

• Under voltage

Controller• Zynq 7020 Series SoC

• Power Distribution Unit

• Power Conversion Unit

Interfaces

 PEPCU
Output Channels

19 x DC Output Channels (Generated from AC3 Input)

• 10x1A

• 4x2A

• 3x2.5A

• 1x20A

 

4 x AC Output Channels

• AC1

o 5.5A (400Hz)

o 5A (400Hz)

• AC2

o 40A(60Hz)

o 5.5A(60Hz)

Discrete Inputs

6 x 28V/GND

21 x Open/Short

Discrete Outputs44 x 28V/GND
Communications

2 x RS485

2 x ETH

Electrical and Mechanical 

 PEPCU
Input Voltage

AC1 440VAC 3 Ph Delta (400 Hz)

AC2 440VAC 3 Ph Delta (60 Hz)

AC3 115VAC 3 Ph Delta (60 Hz)

Dimension (L x W x H) (mm)301.8 x 358 x 165.8
Weight (kg)14.5 ± 0.5

Environmental 

• Operating Temperature: -40°C to +60°C

• MIL-STD-810H

• MIL-STD-704F

• MIL-STD-461F

Current Status

TRL 4/9

Get Quote